| Dimension for Fixed Inserted Vortex Flowmeter & Installation |
| |
|
| Parts: |
|
|
| 1. Converter |
2. Body flange |
3. Duct with flange |
| 4. Outer wall of customer¨s pipe |
5. Inserted rod |
6. Transducer |
| 7. Wall thickness |
8. Customer¨s pipe |
|
|
Installation Procedures:
1. Drill a hole in the customer¨s pipe by method of torch cutting, with diameter slightly less than Φ100, no burr at the edges of the hole to make the measuring probe inserted through it freely.
2. Weld a matched short-duct (supplied by Kent) on the hole on the pipe by spot welding, the axes line of the short-duct is perpendicular 90o to the one of the pipe, as well as its extending line is through the circle center of cross-section of the pipe, then welding all-around.
3. For fixed type
Put gasket of the duct flange, insert probe into the short-duct, then mount bolts and check if it is even around the flange, and the flow direction is conformed.
4. Check all if it is good, open valve slowly and check the leakage (care of personnel safety).
Caution:
1. Flow direction must be conformed with the flow arrow on the meter body;
2. When weld the flange and pipe, the converter should not be installed on the pipe
to avoid any damage of the converter.
|
|