| * Measuring range
¡¡Water (20¡æ) 1 -200000 l/h
¡¡Air (20¡æ, 0.1013MPa) 0.03 - 4000m3/h
¡¡Refer to flowrate table, special flowrate can be ordered.
* Turndown ratio: 10:1 for standard
* Accuracy: ¡À1.5% for local, ¡À1.0% for remote
* Rated pressure: DN15 - DN50 4.0MPa( MaxDN15: 32MPa, DN25:
25MPA, DN50: 20MPa)
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡DN80 - DN250 1.6MPa(MaxDN80: 10MPa, DN100: 6.4MPa,
DN125: 4.0MPa,
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡DN150: 4.0MPa, DN200: 2.5MPa, DN250: 2.5MPa)
* Pressure loss: 7kPa - 70kPa
* Viscosity: DN15: £¼30mPa.s
¡¡¡¡¡¡¡¡¡¡¡¡DN25: £¼250mPa.s
¡¡¡¡¡¡¡¡¡¡¡¡DN50 - DN250: £¼300mPa.s
* Fluid temperature: Local: -80 - +300¡æ
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Remote: -40 - +150¡æ High temperature: 350¡æ
* Ambient temperature: Local: -40 - +80¡æ
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Remote: -40 - +50¡æ
* Connection type: Standard: DIN2501
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Special: specified by user
* Cable connector: M20*1.5
* Power supply: 24V DC
* Output signal: 4 - 20mA DC, HART
* LCD display: Numerical range for instantaneous flowrate:
0 - 50000
¡¡¡¡¡¡¡¡¡¡¡¡¡¡ Numerical range for total flow: 0 - 99999999
* Protection grade: IP65
* Explosion proof: Intrinsical safe: Exia¢òCT5, Certificate
No.: GYB-CE062002
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Flameproof: Exd¢òBT6, Certificate No.: GYB-CE0051423
|