| Structure of Fixed Inserted Electromagnetic Flowmeter & Dimensions |
| |
| Inserted flowmeter consists of transducer (electrode assembly), inserted rod, inserted mechanism (duct, flange etc) and converter (compact and remote) |
|
| Parts: |
|
|
| 1. Converter |
2. Body flange |
3. Duct with flange |
| 4. Outer wall of customer's pipe |
5. Inserted rod |
6. Transducer |
| 7. Wall thickness |
8. Customer's pipe |
|
Working principle: Inserted transducer has the same working principle as the pipe electromagnetic flowmeter, using closed magnetic field according to Faraday¨s Law to ensure stability of flow measuring. This is produced specially by Shanghai Kent, avoiding leakage of magnetic field. Structure is shown as below: |
 |
Technology Data of Inserted Type
* Accuracy: \2.5%
* Repeatability: \0.83%
* Diameter size: DN250 - DN2000
* Straight pipe requirement: 10D for upstream, 3D for downstream
* Converter as same as pipe type |
|
Installation Procedure:
Drilling hole, welding duct, inserting meter, adjusting direction, sealing. Details refer to Electromagnetic flowmeter operation instruction |
|
|