Technical Features
Introduction of KTLDE Electromagnetic Flowmeter
Measuring Principle
How to Select Meter Model Correctly
How to Select Electrode Material
How to Select Liner Material
How to Select Meter Protection Grade & Extra-function
How to Select Meter Installing Location
Installing Site
Wiring
Pattern of Remote Type and Dimensions of Converter
Structure of Fixed Inserted Electromagnetic Flowmeter & Dimensions
Structure of Adjustable Inserted Electromagnetic Flowmeter & Dimensions
Meter Dimensions & Weight
Introduction of Multi Electrodes
Blade Electrode Maintenance and Cleaning
Sanitary Flowmeter Application and Selection
Model Selection
Meter Specification
Pressure Lose of the Diverging and Converging Pipe equipped
KTLDE Electromagnetic Flowmeter
 
¡¡Wiring
 
¡¡¡¡1¡¢Dedicated cable used for remote type electromagnetic flowmeter, the shorter, the better
¡¡¡¡2¡¢YZ rubber conduit used for excitation cable, its length is the same as signal cable
¡¡¡¡3¡¢Signal cable must be isolated with other power cable, do not laid in one conduit or parallel and twisted, should be in the thin wall steel conduit independently
¡¡¡¡4¡¢Keep the signal cable and excitation cable as short as possible, do not wind the exceeding part, which should be cut off and re-weld connector, bend the cable into U shape at the electrical port of the transducer to prevent raining into transducer
¡¡¡¡
Terminals for compact type:
Up line:
T-, T+ ------------RS485 Communication
FUSE-------------Power Fuse
Down line:
AL, AH----------Low/ High limit alarm
P+, COM---------------Pulse Frequency, COM shared with alarm
1+, COM------- 4-20mA
L1, L2------------Power supply 220V(24V DC option)

 
¡¡Terminals for compact local display of flameproof

Up line:
AH------------------------------High limit alarm
T+, T- -------------------------RS 485 communication +, -
SIG1. SGND. SIG2 ---------------4-20mA output
Low line:
EXT+. EXT- ---------------------Excitation current output
IN+ -----------------------------Contact input +
P+. COM -------------------------Pulse/ frequency output, COM shared with alarm
AL ------------------------------Low limit alarm
L1. L2 --------------------------Power supply 220V AC, or 24V DC
 
¡¡Terminal for remote converter of flameproof
  Up Line:   Down Line:  
  IN -
IN +
P+
COM

FDIR
DS1
SIG1
SIG GND
SIG2
DS2
Contact output -
Contact input+
Frequency (Pulse) output +
Frequency(pulse )output ground, shared with FDIR, AL, AH
Flow direction status+
Signal shield 1
Signal 1
Signal ground
Signal 2
Signal shield 2
AL
AH
A
B
COM

EXT-
EXT+
PE
L1
L2
Low limit alarm
High limit alarm
RS 485 output+
RS 485 output
Frequency(pulse )output ground, shared with FDIR, AL, AH
Exciting output -
Exciting output +
Protective ground
AC phase line; DC power supply+
AC zero line; DC power supply¨C
 